-40%
Mikrotik cAP ac RBcAPGi-5acD2nD wireless access point International Version
$ 38.01
- Description
- Size Guide
Description
The cAP ac is a very capable and powerful wireless access point that looks beautiful on both walls and ceilings. The concurrent dual band wireless radio supports dual chain 2 GHz 802.11b/g/n and 5 GHz in a/n/ас standards, and will provide coverage in 360 degrees around it.Even though the radio supports repeater mode, the two Ethernet ports give you the ability to extend your network with cables, even if PoE power is required, since the cAP ac supports 802.3af/at PoE input on the first port, and passive PoE output on the second port.
- cAP ac (International) supports 2412-2484MHz and 5150MHz-5875MHz range (Specific frequency range can be limited by country regulations).
By default, US versions are shipped to all orders that are shipped within the USA. As per the FCC regulations International version cannot be used in the USA unless with a valid license. The customer is responsible for ordering the correct version. You will be requested to sign FCC Authorization form after purchase.
Specifications
Details
Product code
RBcAPGi-5acD2nD
Architecture
ARM 32bit
CPU
IPQ-4018
CPU core count
4
CPU nominal frequency
716 MHz
Dimensions
Round case: ⌀ 136 mm, height: 30 mm; Square case: 145 mm x 145 mm x 30 mm
License level
4
Operating System
RouterOS
Size of RAM
128 MB
Storage size
16 MB
Storage type
FLASH
Tested ambient temperature
-40 to 50° C
Suggested price
.00
Powering
Details
Max Power consumption
13W
PoE in
802.3af/at
PoE out
Passive PoE up to 57V
PoE in input Voltage
17-57 V
Number of DC inputs
1 (PoE-IN)
Wireless
Details
Wireless 2.4 GHz number of chains
2
Wireless 2.4 GHz standards
802.11b/g/n
Antenna gain dBi for 2.4 GHz
2
Wireless 2.4 GHz chip model
IPQ-4018
Wireless 5 GHz number of chains
2
Wireless 5 GHz standards
802.11ac
Antenna gain dBi for 5 GHz
2.5
Wireless 5 GHz chip model
IPQ-4018
Ethernet
Details
10/100/1000 Ethernet ports
2
Wireless specifications
2.4 GHz
Transmit (dBm)
Receive Sensitivity
1MBit/s
26
-100
11MBit/s
26
-94
6MBit/s
26
-96
54MBit/s
23
-78
MCS0
26
-96
MCS7
22
-73
5 GHz
Transmit (dBm)
Receive Sensitivity
6MBit/s
26
-96
54MBit/s
21
-80
MCS0
26
-96
MCS7
20
-75
MCS9
18
-70
Ethernet test results
RBcAPGi-5acD2nD
IPQ-4018 1G all port test
Mode
Configuration
1518 byte
512 byte
64 byte
kpps
Mbps
kpps
Mbps
kpps
Mbps
Bridging
none (fast path)
162.5
1973.4
469.9
1924.7
1484.8
760.2
Bridging
25 bridge filter rules
162.1
1968.5
352.9
1445.5
359.2
183.9
Routing
none (fast path)
162.5
1973.4
469.9
1924.7
1488
761.9
Routing
25 simple queues
162.5
1973.4
469.9
1924.7
506.3
259.2
Routing
25 ip filter rules
162.2
1969.8
240.8
986.3
242.9
124.4
All tests are done with Xena Networks specialized test equipment (XenaBay),and done according to RFC2544 (Xena2544)
Max throughput is determined with 30+ second attempts with 0,1% packet loss tolerance in 64, 512, 1518 byte packet sizes
Values in Italic indicate that max throughput was reached without maxing out CPU, but because board interface configuration was maxed out
Test results show device maximum performance, and are reached using mentioned hardware and software configuration, different configurations most likely will result in lower results
IPsec test results
RBcAPGi-5acD2nD
IPQ-4018 IPsec throughput
Mode
Configuration
1400 byte
512 byte
64 byte
kpps
Mbps
kpps
Mbps
kpps
Mbps
Single tunnel
AES-128-CBC + SHA1
37.9
424.5
59
241.7
61.6
31.5
256 tunnels
AES-128-CBC + SHA1
36
403.2
38.5
157.7
39.8
20.4
256 tunnels
AES-128-CBC + SHA256
36
403.2
38.5
157.7
39.8
20.4
256 tunnels
AES-256-CBC + SHA1
34.4
385.3
37.9
155.2
39.8
20.4
256 tunnels
AES-256-CBC + SHA256
34.4
385.3
37.9
155.2
39.8
20.4
All tests are done with Xena Networks specialized test equipment (XenaBay),and done according to RFC2544 (Xena2544)
Max throughput is determined with 30+ second attempts with 0,1% packet loss tolerance in 64, 512, 1400 byte packet sizes
Test results show device maximum performance, and are reached using mentioned hardware and software configuration, different configurations most likely will result in lower results